1. Shop
  2. Testing Devices for Cables, Magnet Wires and CTC

Insulation testing device
Type HSV 281

Item 39089

Test device for insulation testing of multi-core cables and wires.

• Mobile test device for maximum flexibility
• Test pistols for quick and safe contacting
• Fully automatic test procedure
• Test voltage up to 2,000V DC (adjustable)
• Capacity of the Specimen up to 100μF (other capacities on request)
• Automatic breakdown detection (Sensitivity adjustable)
• Manual discharging of the Specimen after the test
• High operational reliability even in harsh industrial environments

The test device enables standard-compliant insulation tests for..
• Winding wires, Röbel rods and similar products (IEC 60851-5, EN 60851)
• Power transformers (IEC 60076, EN 60076, IEEE C57 series, ANSI C57 series, BS 171)

Specifications

Standard versionUser interface: DE, EN (other languages on request)
Prozess inputTest object
  • Cables or wire bundles with at least 2 conductors insulated from each other.
  • Winding wires, CTC (continuous transposed conductors), Röbel rods and similar products.
  • Capacity of the Specimen: 5nF - 100μF (other capacities on request)
Process flow and detailsTest procedure
  • Contacting two cores with the test pistols.
• Test starts automatically (acoustic and visual signaling).
  • Contacted wires are charged and applied to test voltage.
  • Test ends automatically after the set test period.
  • Test result "OK": acoustic signaling.
  • Test result "Breakdown": acoustic and visual signaling. Confirmation required.
  • You can immedeatly contact the next cores.
  • Safe discharging of the specimen when tests are completed.
Process outputCertainty as to whether the tested Product is in order.
If a breakdown occurs during the test, the insulating layer of the contacted wires is faulty.
InterfacesSupply energy
  • Mains voltage: 1x230V+N+PE, 50Hz AC
  • Connection: Schuko plug. 16 Meter cable on cable reel.
  • Electrical power: approx. 0.4kW
  • Note: Other Mains voltages and frequencies on request (USA).

Energy dissipation
  • Earthing cable: For discharging the residual energies stored in the Specimen.
  • Earthing brush: Not included in Scope of delivery.

On-site measures required
  • Supply line protection: (RCB 1+N, 30mA. CB 1+N 16A C. Overvoltage protection.)
  • Provision and Mounting of an earthing brush suitable for your Product.
InterfacesSupply energy
  • Mains voltage: 1x230V+N+PE, 50Hz AC
  • Connection: Schuko plug. 16 Meter cable on cable reel.
  • Electrical power: approx. 0.4kW
  • Note: Other Mains voltages and frequencies on request (USA).

Energy dissipation
  • Earthing cable: For discharging the residual energies stored in the Specimen.
  • Earthing brush: Not included in Scope of delivery.

On-site measures required
  • Supply line protection: (RCB 1+N, 30mA. CB 1+N 16A C. Overvoltage protection.)
  • Provision and Mounting of an earthing brush suitable for your Product.
Environmental conditions
  • Temperature: +18°C to + 30°C
  • Relative humidity: < 70% non-condensing
  • Air quality: Free from Dust and Contamination. Not Ionized. Not electrically charged.
Dimensions and weight
  • Dimensions (approx.): Width 830mm x Height 1,140 x Depth 860mm
  • Weight: approx. 100 kg

Documents