1. Shop
  2. Production Systems and Testing Equipment for Bimetal-Snap-Action-Discs

Sample Test Equipment
CLICKTEST 10 [CT10]

Item 38941

Test device for determining the snap temperatures and the snap behavior of bimetal elements

• Measuring head for simultaneous testing of up to 16 test objects
• Real time monitoring of snap temperatures
• Real time monitoring of the snap behavior
• Definable temperature profiles (temperature profiles)
• Temperature control from -60°C to +400°C with monitoring and control in real time
• Heating: electric
• Cooling: compressed air and liquid CO2 if required
• Automatic single and multiple measurements
• Statistical evaluation of the measurement data
• Connection to QA systems

Specifications

Standard version
  • Measuring head for simultaneous testing of up to 16 test objects
  • Measuring range: -60°C up to +300°C
  • Real time regulation of the temperature-change-rate
  • Real time monitoring of the snap behavior
  • Detailed evaluation of the snap temperatures
  • Connectivity to QS-systems
Options & Accessories
  • Measuring head Ø20: for snap discs Ø6 to Ø20mm
  • Measuring head Ø30: for snap discs Ø10 to Ø30mm
  • Extended measuring range for temperatures from +300°C to +400°C
  • Monitoring the snap behavior of electrical contacts (creeping)
  • Elimination of the CO2 bottle frame (e.g. if a stationary CO2 supply is available)
CapacityThe measurement duration depends on the set parameters.
  • Maximum temperature change rate: 40 ° C / min
  • Recommended temperature change rate: 5°C / min in the tolerance range of the snap temperatures
Process Input
  • Bimetal snap-action elements (isolated)
  • Disc-diameter: max. 20mm resp. 30mm (according to measuring head)
Process flow and details
  • Bimetal snap-action elements are manually inserted into the measuring head.
  • Test parameters are selected. Test process is started.
  • Bimetallic snap elements are heated up and cooled down in accordance with the set temperature profile.
  • Temperature change rate: up to 40 ° C / min
  • The snap temperatures (TOS, TUS) are recorded with an accuracy of +/- 0.01 ° C.
  • The snap behavior is recorded.
  • Depending on the parameterization, this process is carried out one or more times.
  • A detailed evaluation of the results is provided as a report.
Process output
  • Test objects, measured and isolated
Interfaces
  • Mains voltage: 1x230V+N+PE, 50/60Hz AC
  • Electrical power: approx. 1.2 kW
  • Compressed air: 6.0 - 10 bar. 300 liters / minute. Free from oil, water and dust.
  • Different mains voltages and frequencies on request.
Environmental conditions
  • Industry standard. Indoor.
  • Temperature: + 18°C to + 30°C
  • Relative humidity: < 70% non-condensing
Dimensions and weightTest device (Width x High x Depth): approx. 1,500 x 1,300 x 800mm
Space requirement (Width x High x Depth): approx. 2,000 x 2,100 x 1,500mm
Weight: about 250kg